Search results for " nail"
showing 10 items of 31 documents
Electromagnetic distal targeting system does not reduce the overall operative time of the intramedullary nailing for humeral shaft fractures
2018
Abstract Introduction We aimed to evaluate the efficacy of the use of the electromagnetic distal targeting system in treating humeral shaft fracture. Methods Patients were divided in: Group 1) patients that received a distal locking screw placement following the free-hand technique; Group 2) patients in which the distal locking screw was performed using the SURESHOT device. Results No differences were noted comparing Group 1 (freehand) [71,9 range 40–135 min] to Group 2 (SURESHOT)[70, range 25–125 min]. Conclusion The use of the EM distal targeting system doesn't reduce the overall operative time of the humeral shaft fracture fixation using IMN.
The challenges of monoaxial bone transport in orthopedics and traumatology
2017
Background. Bone defects represent the main challenging problem for the orthopedic surgeon and, consequently, they increase the duration of hospitalization, risk of complications and health expenditures. The aim of our observational, descriptive and retrospective study is to evaluate the outcomes of patients treated with a monolateral external fixator for bone defects greater than 3 cm. Material and methods. Between January 2003 and January 2013, 21 patients were treated at our center by bone transfer with a monolateral external fixator. The main etiologies were trauma in 17 cases (80.9%) and tumors in 4 cases (19.1%). Mean follow-up was 5 years for non-union and 3 years for tumors. Our cl…
Incidence of onychomycosis among psoriatic patients with nail involvement: a descriptive study
2013
Clinical performance of a new medullary humeral nail: antegrade versus retrograde insertion.
2001
Objective A new intramedullary nail system for humeral shaft fractures is evaluated to determine whether retrograde nailing is as reliable as antegrade nailing. Study design Prospective multicenter nonrandomized clinical study. Patients Eighty-four patients with acute humeral shaft fractures were nailed with the new unreamed humeral nail (UHN) system. Fifty-seven nails were introduced retrogradely, and twenty-seven antegradely. Bone healing and functional outcome were the follow-up parameters. Results The ratio of perioperative complications was equivalent for both groups, but one shaft fracture and three fractures or fissures at the entry point occurred in the group with retrograde nail in…
A comparison between nailfold capillaroscopy patterns in adulthood in juvenile and adult-onset systemic sclerosis: A EUSTAR exploratory study.
2015
Objective: Qualitative capillaroscopy patterns in juvenile- and adult-onset systemic sclerosis (SSc) were studied in adulthood using data from the EULAR Scleroderma Trials and Research (EUSTAR) database. Methods: Data collected between June 2004 and April 2013 were examined with focus on capillaroscopy. In this retrospective exploratory study, series of patients with juvenile-onset SSc were matched with series of adult-onset SSc having the same gender and autoantibody profile. Results: 30 of 123 patients with juvenile-onset and 2108 of 7133 with adult-onset SSc had data on capillaroscopy. Juvenile-onset SSc showed scleroderma pattern more frequently than adult-onset SSc (93.3% and 88%). The…
The treatment of wrist fractures with Epibloc System
2011
BACKGROUND Fractures of the distal extremity of the radius are the most common bone lesions of the superior extremity of the body, representing 17% of the fractures treated in First Aid facilities. The restoration of anatomical relationships in the radiocarpal joint is considered to be a prerequisite for good functional recovery. There are numerous methods of treatment of these fractures. The Epibloc system is a percutaneous endomedullary synthesis alternative to the plaster cast in wrist fracture treatment. MATERIALS AND METHODS The authors describe their experience with 81 fractures (63 type A2-3 fractures and 18 type C1) of the wrist treated with the Epibloc System (ES). The results were…
Implantation of a polycaprolactone scaffold with subchondral bone anchoring ameliorates nodules formation and other tissue alterations
2015
Purpose: Articular cartilage has limited repair capacity. Two different implant devices for articular cartilage regeneration were tested in vivo in a sheep model to evaluate the effect of subchondral bone anchoring for tissue repair. Methods: The implants were placed with press-fit technique in a cartilage defect after microfracture surgery in the femoral condyle of the knee joint of the sheep and histologic and mechanical evaluation was done 4.5 months later. The first group consisted of a biodegradable polycaprolactone (PCL) scaffold with double porosity. The second test group consisted of a PCL scaffold attached to a poly(L-lactic acid) (PLLA) pin anchored to the subchondral bone. Result…
The challenge of open tibial shaft fractures: When tomanage with external fixation and when to useintramedullary nailing?
2020
Treatment of open tibial shaft fractures is challenging. External fixation (EF) is comparatively safe in treating these open injuries with the main advantages of easy application, minimal additional disruption, and convenient subsequent soft tissue repair. Tibial intramedullary nailing (IM) is optimal for the treatment of open tibial fractures. This study aims to report the outcomes of our multi-center experience in the management of open tibial shaft fractures, evaluating the efficacy and safety of using either the external fixation (EF) or intramedullary nailing (IM).In this study, clinical-radiographic results were evaluated in 26 cases of open fractures treated with an external fixator …